Critical Environment Technologies PDC Series Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Detektory tlenku węgla (CO) Critical Environment Technologies PDC Series. Critical Environment Technologies PDC Series Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 34
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
1
Critical Environment Technologies Canada Inc.
“PDC”
Series
Programmable Digital Controllers &
“DST” Series Digital Sensor / Transmitters
Critical Environment Technologies Canada Inc.
Unit 145, 7391 Vantage Way Delta, BC V4G 1M3
Canada Ph: 604-940-8741 Fx: 604-940-8745
www.critical-environment.com
INSTALLATION / OPERATION MANUAL
REV: G Feb 01, 2013
Przeglądanie stron 0
1 2 3 4 5 6 ... 33 34

Podsumowanie treści

Strona 1 - REV: G Feb 01, 2013

1 Critical Environment Technologies Canada Inc. “PDC” Series Programmable Digital Controllers & “DST” Series Digital Sensor / Transmitters Criti

Strona 2

10 4.1 ENCLOSURE INTERIOR LAYOUT PHOTO INCOMING LINE VOLTAGE SYSTEM POWER ENCLOSURE MOUNTING HOLE ENCLOSURE MOUNTING HOLE ENCLOSURE MOUNTING HOLE EN

Strona 3

11 4.2 WIRING CONNECTIONS DRAWING (DIGITAL)

Strona 4 - 1.0 GENERAL

12 4.3 WIRING CONNECTIONS DRAWING (ANALOG)

Strona 5

13 4.4 DST DIGITAL ELECTROCHEMICAL SENSOR / TRANSMITTER DRAWING

Strona 6 - 3.1 WIRING

14 4.5 DST DIGITAL SOLID-STATE SENSOR / TRANSMITTER DRAWING

Strona 7

15 5.0 MAIN CIRCUIT BOARD PHOTO DIGITAL “J3” JUMPER LOCATION FOR “SYSTEM RESET” SECOND CAN WIRING TERMINAL STRIP “J5” JUMPER LOCATION FOR THE BOTH CA

Strona 8 - Installation Example-1:

16 5.1 MAIN CIRCUIT BOARD PHOTO ANALOG WIRING TERMINAL STRIP FOR INDIVIDUAL ANALOG SIGNAL WIRES FROM ANALOG TRANSMITTERS WIRING TERMINAL STRIP SUPPLY

Strona 9

17 5.2 DST CIRCUIT BOARD PHOTO (ELECTROCHEMICAL) WIRING INPUT TERMINALS WIRING OUTPUT TERMINALS LINK LED AUTO-CAL PUSH-BUTTON LED-2 FOR CALIBRATI

Strona 10

18 6.0 SYSTEM OPERATION Powering up: Double check wiring connections at both the PDC controller and the remote mounted DST series digital transmitt

Strona 11

19 7.0 SYSTEM PROGRAMMING– GENERAL System Configuration: The PDC controller is completely configurable by the end user. Reference the following pag

Strona 12

2 IMPORTANT NOTICES READ AND UNDERSTAND THIS OPERATION MANUAL PRIOR TO INSTALLING OR USING THIS INSTRUMENT. THE MANUFACTURER IS NOT RESPONSIBLE

Strona 13

20 7.2 INPUT CODE DESCRIPTIONS 1211 “LOW ALARM SET POINT”: This code allows the user to set or change the system low alarm set point. This is th

Strona 14

21 7.2 INPUT CODE DESCRIPTIONS, CONT’D….. 3212 “ INPUT ADDRESS”: This code is used to initiate and configure the system. First ensure all external

Strona 15

22 7.2 INPUT CODE DESCRIPTIONS, CONT’D….. 1221 “AUTO NULL”: This code allows the user to force the remote DST (digital signal transmitter) to nul

Strona 16

23 7.2 INPUT CODE DESCRIPTIONS, CONT’D….. GAS SENSOPR TYPE - CODE 1231 - GAS SENSOR LISTING DISPLAY GAS SENSOR UNITS INDICATION TY

Strona 17

24 7.3 SYSTEM PROGRAMMING - OUTPUT CODES CODE DESCRIPTION 2331 NORMAL RELAY ACTIVATE (GAS ALARM) (ALL , SENS ,

Strona 18 - 6.0 SYSTEM OPERATION

25 7.4 OUTPUT CODE DESCRIPTIONS 2331 “NORMAL RELAY ACTIVATE (GAS ALARM)”: This menu item is used to select the type of alarms which will activate e

Strona 19

26 7.4 OUTPUT CODE DESCRIPTIONS, CONT’D….. 3221 “RELAY ENABLE / DISABLE”: This code allows the user to enable or disable a specific relay. The c

Strona 20 - 7.2 INPUT CODE DESCRIPTIONS

27 7.4 OUTPUT CODE DESCRIPTIONS, CONT’D….. 2333 “STROBE OUTPUT ACTIVATION LEVEL”: This code controls the gas alarm level at which the “strobe” o

Strona 21

28 7.4 OUTPUT CODE DESCRIPTIONS, CONT’D….. 3232 “REMOTE ANALOG OUTPUT ADDRESS INITIALIZATION”: This code allows the user to add remote analog out

Strona 22

29 7.4 OUTPUT CODE DESCRIPTIONS, CONT’D….. 3332 “MESSURE ANALOG INPUT VOLTAGES”: This code allows the user to measure the analog input without hav

Strona 23

3 INDEX SECTION DESCRIPTION PAGE 1.0 General ...

Strona 24

30 8.0 CALIBRATION OF SENSOR / TRANSMITTERS Frequency: All sensors require regular calibration maintenance to ensure accuracy and indeed to confi

Strona 25

31 9.0 PERIPHERAL DEVICES Extra Relays: If the target application will require more than eight relay contacts, optional remote relay modules (M/N R

Strona 26

32 12.0 TROUBLE-SHOOTING If after 10 min of operation there are errors in the system the following check list should be carried out. 1) Check tha

Strona 27

33 12.0 TROUBLE-SHOOTING, CONT’D….. With the POWER ON 1) Check the voltage on the 24VDC line. A reading of anywhere between 24.0 VDC to 20.0VDC is

Strona 28

34 12.0 TROUBLE-SHOOTING, CONT’D….. Software 1) Check System Error/WDT Test Menu 3331. The display will indicate what the source of the error is t

Strona 29

4 1.0 GENERAL PDC series systems are configurable, digital, microprocessor based, controllers for use in non-hazardous (non-explosion rated) envi

Strona 30

5 2.0 CONTROLLER SPECIFICATIONS, CONT’D….. Fuses: Replaceable: Primary: 1.5 amp, Power supply: 2.0 amp Options: a) BACnet Output Mod

Strona 31 - 11.0 MODEL AND PART NUMBERS

6 3.0 INSTALLATION Standard: Four 3/16” diameter mounting holes can be located at the corners inside the enclosure base. Take caution when using in

Strona 32 - 12.0 TROUBLE-SHOOTING

7 3.1 WIRING Digital System: If a digital system has been selected, refer to “WIRING SPECIFICATIONS AND INSTALLATION INSTRUCTIONS” on page 5. The

Strona 33

8 3.2 JUMPER SETTINGS AND WIRING EXAMPLES, CONT’D….. System wiring can originate at the “CAN-IN” or “CAN-OUT” wiring terminals of the PDC. They are

Strona 34

9 NOTE-1: Three knockouts can be found along the top edge and three along the bottom edge of the system enclosure NOTE-2: Standard enclosure is pow

Komentarze do niniejszej Instrukcji