Critical Environment Technologies AST-IS5 Instrukcja Użytkownika Strona 1

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Nie Critical Environment Technologies AST-IS5. AST-IS5 Carbon Dioxide Transmitter [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
Critical Environment Technologies
Canada Inc.
www.critical-environment.com
Installation Manual for
AST-IS5
Analog transmitters with Infrared CO
2
& Temperature sensors with LCD display & relay
#145, 7391 VANTAGE WAY
DELTA, BC CANADA V4G 1M3
PH: 604-940-8741 TOLL FREE: 877-940-8741
MANUAL REVISION-C, February 24, 2015
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - AST-IS5

Critical Environment Technologies Canada Inc. www.critical-environment.com Installation Manual for AST-IS5 Analog transmitters with Infrared CO2 &am

Strona 2

10 ITEM LOCATORS 1 top portion 2 lid 3 front portion 4 wall plate 5 screw 6 label with settings inside the top portion DRAWING #1 INSTALLING THE TRA

Strona 3

11 INSTALLING THE TRANSMITTER, CONT’D….. REMOVE THE SECURING SCREW FROM THE TOP PORTION, ITEM-5 IN ITEM LOCATOR ON PREVIOUS PAGE PULL THE TOP PORTION

Strona 4

12 INSTALLING THE TRANSMITTER, CONT’D….. SECURE THE WALL PLATE WITH SCREWS. MAXIMUM SCREW HEAD DIAM-TER SHOULD BE 7.5 mm. MAXIMUM SCREW HEAD HEIGHT SH

Strona 5

13 INSTALLING THE TRANSMITTER, CONT’D….. THE TOP PORTION IS PUSHED UNDER THE LOCKING HOOKS OF THE WALL PLATE AND IS SECURED WITH A SCREW TERMINALS &am

Strona 6

14 WIRING TERMINALS & SIGNAL OUTPUT JUMPER SETTINGS OUT-2 OUT-1 + POWER 24VAC / DC+ POWER GROUND (-) ANALOG OUT 4-20mA(+) CO2 ANALOG OUT 2-10VDC

Strona 7

15 Connection Terminal Function Electrical Data Remarks G+ G0 Power (+) Power ground (-) 24 VAC/DC+ (+-20%), 3W 24 VAC/DC- 2W w

Strona 8 - TECHNICAL SPECIFICATIONS

16 AST20150224-C-AST-IS5-Manual-Rev-C Critical Environment Technologies Canada Inc. Unit 145, 7391 Vantage Way, Delta, BC, V4G 1M3, Canada Toll Free:

Strona 9 - OUTPUT CONFIGURATIONS

2 This product is in accordance with EMC 2004/108/EC, 92/31/EEG including amendments by the CE-marking Directive

Strona 10 - INSTALLING THE TRANSMITTER

3 IMPORTANT NOTE Read and understand this manual prior to using this instrument. Carefully read the warranty policy, service policy, notices, disclaim

Strona 11

4 Due to ongoing research, development, and product testing, the manufacturer re-serves the right to change specifications without notice. The informa

Strona 12

5 national and domestic copyright laws, this manual may not be copied or translated, in whole or in part, in any manner or format, without the written

Strona 13

6 AST-IS5 ANALOG TRANSMITTER with INFRARED CO2 SENSOR & TEMPERATURE SENSOR and LCD DIGITAL DISPLAY The AST-IS series are reliable, long li

Strona 14 - PAGE-7 FOR MORE DETAILS

7 FUNCTIONAL DESCRIPTION OUT-1 = Measuring signal of CO2 concentration lowest value - highest value. OUT-2 = Measuring signal of temperature lowest v

Strona 15

8 TECHNICAL SPECIFICATIONS GAS TYPE Carbon Dioxide (CO2) MECHANICAL Enclosure General Purpose PVC., IP30 rated Size 4.7” x 3.2” x 1.2” (120mm x 8

Strona 16

9 TERMINAL DEFAULT OUTPUT DEFAULT OUTPUT RANGE OUTPUTS OF THIS SENSOR OUTPUT RANGE OF THIS SENSOR OUT-1 4-20 mA 0-2000 ppm CO2 OUT-2 2-10 VDC